Safety Power Rail & Cable Festoon System

prostar logo white_工作區域 1.png

3P.4P.6P Safety Power Rail

  • 3P ( 3 Pole / Phase )
    50A.75A.100A.150A.200A
    ( 3P is used for 3 Phase R.S.T. )

 

  • 4P ( 4 Pole / Phase )
    50A.75A.100A.150A.200A
    ( 4P is used for 3 Phase R.S.T. & Ground )

 

  • 6P ( 6 Pole / Phase )
    50A.75A.100
    ( 6P is used for 3 Phase R.S.T. & Extra 3 pole for end carrier )

 3P.4P.6P SAFETY POWER RAIL COMPONENTS

  • End Tension & Power In

End Tension & Power In-1.jpg
End Tension & Power In-2.jpg
End Tension & Power In-3.png
  • Insulated Conductor Rails

Insulated Conductor Rails-1.jpg
Insulated Conductor Rails-2.jpg

Material of Conductor : Copper
Material of Insulator : PVC (Up to 60°C) 

Insulated Conductor Rails_3p.png
Insulated Conductor Rails_4p.png
Insulated Conductor Rails_6p.png
  • Collector

  • Collector is only for replacement that is a consuming parts of Current Collector.

Collector-1.jpg
Collector-2.jpg
Collector-3.png
  • Supports

Supports-1.jpg
Supports-2.jpg

For a clearer picture display, please visit computer version of the website.

Supports-3.png
  • Hanger Clamp

Hanger Clamp-1.jpg
Hanger Clamp-2.jpg
Hanger Clamp-3.png
  • Current Collector

Current Collector-1.jpg
Current Collector-2.jpg
Current Collector-3.png
  • Middle Power Feeding

  • Middle Power Feeding is used for connecting the Insulated Conductor Rails that will be extended or the length of the Insulated Conductor Rails is over 100 meters to avoid voltage dropping.

Middle Power Feeding-1.jpg
Middle Power Feeding-2.jpg
Middle Power Feeding-3.png
  • Fix Square Bar

  • H307 Fix Square Bar is used for 3P, 4P & 6P Insulated Conductor Rails System.

  • HI07 Fix Square Bar is used for I-Type & W-Type Insulated Conductor Rails System.

Fix Square Bar-1.jpg
Fix Square Bar-2.jpg
Fix Square Bar-3.png
Components

 3P.4P.6P SAFETY POWER RAIL OUTLINE DESIGN

Power rail DM 2013-9-01.jpg

50Amp Insulated Conductor Rails is applied in a small type cranes (1~3 tons). 

150Amp Insulated Conductor Rails is applied in a multiple type cranes (5~10 tons).

  • Side Installation

Power rail DM 2013-9-02.jpg
Power rail DM 2013-9-03.jpg
  • Vertical Installation

  • Supports Design

Power rail DM 2013-10-01.jpg
  • The Side Installation is necessary if the 3P.4P.6P Insulated Conductor Rails is mounted at a radian. 

  • To install a Hanger Clamp in each 0.5 meter from the start point of the radian.

  • The End Tension & Power In of 3P.4P.6P Insulated Conductor Rails have to be installed 5mm higher than the Hanger Clamp to avoid water flowing down to make short circuit. 

 *** The weathered protection is required if 3P.4P.6P Insulated Conductor Rails is applied in outdoors.

 (1) How to install End Tension & Power In

Power rail DM 2013-10-1a.jpg

 A 

Power rail DM 2013-10-1b.jpg

 B 

Power rail DM 2013-10-1c.jpg

 C 

 (2) How to install Hanger Clamp

Power rail DM 2013-10-2a.jpg

 A 

Power rail DM 2013-10-2b.jpg

 B 

Power rail DM 2013-10-2c.jpg

 C 

 (3) How to install Fix Square Bar and Current Collector

Power rail DM 2013-11-3a.jpg

 A 

Power rail DM 2013-11-3c.jpg

 C 

Power rail DM 2013-11-3b.jpg

 B 

 (4) How to install Middle Power Feeding

Power rail DM 2013-11-4a.jpg

 A 

Power rail DM 2013-11-4b.jpg

 B 

Power rail DM 2013-11-4c.jpg

 C 