Safety Power Rail & Cable Festoon System
3P.4P.6P Safety Power Rail
-
3P ( 3 Pole / Phase )
50A.75A.100A.150A.200A
( 3P is used for 3 Phase R.S.T. )
-
4P ( 4 Pole / Phase )
50A.75A.100A.150A.200A
( 4P is used for 3 Phase R.S.T. & Ground )
-
6P ( 6 Pole / Phase )
50A.75A.100
( 6P is used for 3 Phase R.S.T. & Extra 3 pole for end carrier )
3P.4P.6P SAFETY POWER RAIL COMPONENTS
-
End Tension & Power In
-
Insulated Conductor Rails
Material of Conductor : Copper
Material of Insulator : PVC (Up to 60°C)
-
Collector
-
Collector is only for replacement that is a consuming parts of Current Collector.
-
Supports
For a clearer picture display, please visit computer version of the website.
-
Hanger Clamp
-
Current Collector
-
Middle Power Feeding
-
Middle Power Feeding is used for connecting the Insulated Conductor Rails that will be extended or the length of the Insulated Conductor Rails is over 100 meters to avoid voltage dropping.
-
Fix Square Bar
-
H307 Fix Square Bar is used for 3P, 4P & 6P Insulated Conductor Rails System.
-
HI07 Fix Square Bar is used for I-Type & W-Type Insulated Conductor Rails System.
3P.4P.6P SAFETY POWER RAIL OUTLINE DESIGN
50Amp Insulated Conductor Rails is applied in a small type cranes (1~3 tons).
150Amp Insulated Conductor Rails is applied in a multiple type cranes (5~10 tons).
-
Side Installation
-
Vertical Installation
-
Supports Design
-
The Side Installation is necessary if the 3P.4P.6P Insulated Conductor Rails is mounted at a radian.
-
To install a Hanger Clamp in each 0.5 meter from the start point of the radian.
-
The End Tension & Power In of 3P.4P.6P Insulated Conductor Rails have to be installed 5mm higher than the Hanger Clamp to avoid water flowing down to make short circuit.
*** The weathered protection is required if 3P.4P.6P Insulated Conductor Rails is applied in outdoors.